Nötron Valf

Cast Steel Gate Valves

ASA 600

This type of valves are used in places where pressure drop is not required during flow.

They are used either fully open or fully closed.

If they are used in the half-open position, the speed of the fluid passing through causes the bolt to vibrate and consequently damage it.

Gate valves cannot be throttled.

ASA 600 Figure V 2030
Measure Ø B Ø G Ø R C Ø dxn D H Ø M App. W
inch mm mm mm mm mm mm mm mm mm kg
2 50 165,1 127 92 25,4 19 x 8 292,1 375 200 36
2 ½ 65 190,5 149,3 104,8 28,4 22,2 x 8 330,2 415 230 42
3 80 209,6 168,3 127 31,8 22,2 x 8 355,6 455 250 75
4 100 273 215,9 157,2 38,1 25,4 x 8 431,8 555 350 123
6 150 355,6 292,1 215,9 47,8 28,5 x 12 558,8 800 500 290
8 200 419,1 349,2 269,9 55,6 31,8 x 12 660,4 930 600 420
10 250 508 431,8 323,8 63,5 35 x 16 787,4 1125 800 700
12 300 558,8 489 381 66,5 35 x 20 838,2 1400 800 1020
14 350 603,3 527 412,8 69,9 38,1 x 20 889 1570 800 1450
16 400 685,8 603,2 469,9 76,2 41,1 x 20 990,6 1625 800 1820
18 450 743 654 533,4 82,6 44,5 x 20 1092,2 2250 1000 1990
20 500 812,8 723,9 584,2 88,9 44,5 x 24 1193,8 2400 1400 2410
24 600 939,8 838,2 692,2 101,6 50,8 x 24 1397 3000 1500 3990